Victron Energy
Victron Energy Quattro 12/5000/220-100/100 120V Inverter Charger, 5000VA 4000W, 220A Charger, Dual 100A AC Inputs, QUA125021100
Victron Energy Quattro 12/5000/220-100/100 120V Inverter Charger, 5000VA 4000W, 220A Charger, Dual 100A AC Inputs, QUA125021100
- Regular price
- Price: $2,834.75
- Regular price
- List Price: $0.00
- Sale price
- Price: $2,834.75
- Unit price
- / per
Notify me when this product is available:
Couldn't load pickup availability
PRODUCT DESCRIPTION
- 🇺🇸Free ShippingContiguous 48 states
- 🛡️5-Year WarrantyVictron limited warranty
- 🔌Two AC InputsShore + generator, auto select
- 🔀Grows With YouParallel, split & 3-phase
- ⚡3-in-1 UnitInverter, charger & transfer switch
- 📞Real Human SupportSystem sizing & setup help
Victron Energy Quattro 12/5000/220-100/100 120V (QUA125021100): a pure sine wave inverter, battery charger and dual-input automatic transfer switch in one unit. Run 120V AC loads from your 12V battery bank with 5000 VA / 4000 W of continuous pure sine wave power and 10,000 W peak. Two AC inputs, each with a 100 A transfer switch, let you connect shore power and a generator at the same time, and the Quattro switches to the active source automatically. Whenever AC is available, the 220 A charger refills your batteries; if the AC source drops out, the no-break output keeps computers and electronics running. PowerControl, PowerAssist and Victron GX/ESS compatibility make it a go-to for larger RV, marine, off-grid and home backup systems. Backed by Victron's 5-year limited warranty.
Ratings at 25°C (77°F) ambient, from Victron's datasheet. Output drops at higher temperatures, see the table below.
⚡ Is It Right for Your System?
Built for 12V battery banks powering standard 120V 60 Hz North American AC loads from two AC sources. Common uses:
- Large RVs & motorhomes
- Yachts & workboats
- Off-grid homes & cabins
- Home backup with generator
- Commercial & remote sites
- Your battery bank is 12V (inverter input range 9.5–17 V). Victron recommends at least 800 Ah (800–2400 Ah).
- You need 120V single-phase output. Need 240V? Two identical units can be set up for 120/240V split phase, or look at the Quattro-II 2x120V in the table below.
- Your AC loads stay within 4000 W continuous at 25°C, with short surges up to 10,000 W.
- Each AC input carries up to 100 A. PowerControl lets you set a lower limit for a small generator or shore pedestal.
- Plan for battery cables, a DC fuse and AC wiring sized per Victron's manual (not included).
- Need UL for an RV, inspection or permit? This version isn't UL listed. See the UL models in the table below.
Why Choose a Victron Quattro
Two AC Inputs
Connect shore power and a generator, or two generators. The Quattro picks the live source automatically, with AC-in-1 taking priority.
Two 100 A Transfer Switches
Each input passes up to 100 A through to your loads, so a large AC panel keeps running on shore or generator power.
PowerControl & PowerAssist
Set a separate current limit for each input. When loads spike past it, the Quattro adds battery power so the breaker doesn't trip.
No-Break Output
If the AC source fails, the main output switches to inverter power fast enough that computers keep running. A second output powers loads only while AC is present.
Expandable
Two identical units give 120/240V split phase, three give three-phase, and up to 6 can run in parallel per Victron's manual.
5-Year Victron Warranty
Victron covers the Quattro for 5 years from purchase by the original end user, and warranty claims go through us.
🎥 Setup & Firmware Videos from Victron
VEConfigure basics: setting up a Victron inverter/charger
Update VE.Bus firmware from an Android phone
🌡️ Output vs. Temperature
| Ambient temperature | Continuous output |
|---|---|
| 25°C (77°F) | 5000 VA / 4000 W |
| 40°C (104°F) | 3700 W |
| 65°C (149°F) | 3000 W |
| Peak (short surges) | 10,000 W |
Per Victron's datasheet. Mount it somewhere cool and well ventilated to get the most out of it.
📦 What's Included & What You'll Need
-
Victron Quattro 12/5000/220-100/100 120VPart number QUA125021100
- Battery Temperature SensorIncluded, per Victron's manual
- Battery Cables & DC FuseNot included. Victron's manual calls for an 800 A DC fuse and 2× 120 mm² (about 4/0 AWG) cable per terminal for runs up to 5 m
- GX Device (recommended)e.g. Cerbo GX for ESS, lithium BMS integration and VRM remote monitoring. Sold separately
- Programming InterfaceMK3-USB (VEConfigure) or VE.Bus Smart dongle (VictronConnect). Sold separately
🔍 Compare Victron Quattro Models
Every Quattro and Quattro-II we carry, side by side. Ratings are Victron's, at 25°C.
| Model | Part # | Battery | Inverter | Charger | AC inputs | AC type | UL |
|---|---|---|---|---|---|---|---|
| Quattro 12/5000/220-100/100 120V (this model) | QUA125021100 | 12V | 5000 VA / 4000 W | 220 A | 2 × 100 A | 120V | Not UL listed |
| Quattro 12/5000/220-100/100 120V UL | QUA125021102 | 12V | 5000 VA / 4000 W | 220 A | 2 × 100 A | 120V | UL 458 |
| Quattro 24/5000/120-100/100 120V | QUA245023110 | 24V | 5000 VA / 4000 W | 120 A | 2 × 100 A | 120V | Not UL listed |
| Quattro 24/5000/120-100/100 120V UL | QUA242503112 | 24V | 5000 VA / 4000 W | 120 A | 2 × 100 A | 120V | UL 458 |
| Quattro 48/5000/70-100/100 120V UL | QUA482501102 | 48V | 5000 VA / 4000 W | 70 A | 2 × 100 A | 120V | UL 1741 |
| Quattro 48/10000/140-100/100 120V | QUA483100100 | 48V | 10,000 VA / 8000 W | 140 A | 2 × 100 A | 120V | Not UL listed |
| Quattro 48/10000/140-100/100 120V UL | QUA483100102 | 48V | 10,000 VA / 8000 W | 140 A | 2 × 100 A | 120V | UL 1741 |
| Quattro 48/10000/140-100/100 120V 50/60Hz | QUA483100300 | 48V | 10,000 VA / 8000 W | 140 A | 2 × 100 A | 120V | Not UL listed |
| Quattro-II 12/3000/120-50/50 2x120V | QUA122305130 | 12V | 3000 VA / 2400 W | 120 A | 2 × 50 A (split phase) | 2×120V (split-phase input) | Not UL listed |
| Quattro-II 24/3000/70-50/50 2x120V | QUA242305130 | 24V | 3000 VA / 2400 W | 70 A | 2 × 50 A (split phase) | 2×120V (split-phase input) | Not UL listed |
Need help choosing? Call 833-664-7433 and we'll size it to your loads.
🔋 Charging Your Batteries
Lithium or Lead-Acid
Adaptive 4-stage charging with default voltages of 14.4 V / 13.8 V / 13.2 V (absorption / float / storage). Adjust them with VEConfigure or VictronConnect, or let a GX device and your lithium BMS control charging.
From Either AC Input
Charges from whichever AC input is live, shore or generator, and PowerControl keeps it within your source's limit.
Starter Battery Output
A separate 4 A output keeps an engine or starter battery charged.
Temperature Compensation
A battery temperature sensor adjusts charging for hot and cold conditions. The sensor comes with the unit.
🛡️ 5-Year Victron Limited Warranty
Warranty claims are made through the place of purchase, which is us. Victron's warranty doesn't cover physical damage or alteration, misuse (reversed polarity, poor or loose connections, liquid or condensation, lightning), improper installation, repairs by anyone other than Victron or an authorized repair centre, or the cost of removal, shipping and reinstallation. Full terms in Victron's warranty policy below.
📋 Full Specifications
| Inverter | |
| Model / Part Number | Quattro 12/5000/220-100/100 120V / QUA125021100 |
|---|---|
| Battery Voltage | 12V (input range 9.5–17 V) |
| AC Output | 120 VAC ±2%, 60 Hz ±0.1% |
| Continuous Power at 25°C | 5000 VA / 4000 W |
| Continuous Power at 40°C / 65°C | 3700 W / 3000 W |
| Peak Power | 10,000 W |
| Max Efficiency | 94% (the manual lists 90%) |
| Zero-Load / AES / Search Mode | 30 W / 20 W / 10 W |
| Charger & AC | |
| AC Input | Two inputs, 90–140 VAC, 55–65 Hz, power factor 1 |
| Input Priority | AC-in-1 has priority when both inputs are live |
| Charge Voltage (absorption / float / storage) | 14.4 V / 13.8 V / 13.2 V |
| Max Charge Current | 220 A per Victron's model name, price list and manual (the datasheet lists 200 A) |
| Starter Battery Charge Current | 4 A |
| Battery Temperature Sensor | Yes, included |
| Transfer Switch / Max AC Input | 100 A on each input |
| Transfer Time | UPS function; fast enough that computers keep running (Victron doesn't publish a figure) |
| AC-out-2 | 50 A, live only when an AC input is present |
| PowerControl / PowerAssist | Yes, adjustable 14–100 A per input (factory defaults 60 A on AC-in-1, 30 A on AC-in-2) |
| System & Control | |
| ESS (Energy Storage System) | Supported with a GX device. Check your utility's interconnection rules before exporting power |
| Parallel / 3-Phase | Up to 6 in parallel (per manual); 2 units for 120/240V split phase; 3 units for three-phase (wye, not delta) |
| Programmable Relay | 3 relays (120 VAC / 4 A; 4 A up to 35 VDC, 1 A up to 60 VDC); alarm, low DC voltage or genset start/stop |
| Ports | VE.Bus, 2× general-purpose com ports, remote on/off |
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 120 VAC on inverter output, input voltage ripple too high |
| Operating Temperature | -40 to +65°C |
| Humidity | Max 95%, non-condensing |
| Enclosure & Certifications | |
| Enclosure | Aluminium, blue (RAL 5012) |
| Protection Category | IP21 |
| Battery Connection | Four M8 bolts (2 positive, 2 negative) |
| AC Connection | Bolt terminals. Per Victron's manual: AC inputs min. 2 AWG, AC-out-1 min. 1/0 AWG, AC-out-2 min. 6 AWG |
| Weight | 34 kg (75 lb) |
| Dimensions (H × W × D) | 470 × 350 × 280 mm (18.5 × 14.0 × 11.2 in) |
| Safety Standards | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1; ECE R10-5 |
| Recommended DC Fuse & Cable | 800 A DC fuse and 2× 120 mm² (about 4/0 AWG) cable per terminal for runs up to 5 m (per Victron's manual) |
| Recommended Battery Bank | 800–2400 Ah (per Victron's manual) |
| Warranty | 5-year Victron limited warranty |
📄 Manuals & Downloads
Victron doesn't publish a box contents list for the Quattro. Manuals, drawings and certificates above link straight to Victron.
❓ Common Questions
What's the difference between a Quattro and a MultiPlus?
Will it start my air conditioner, microwave or pump?
Will it work on smaller shore power or a small generator?
Can I get 240V from it?
Can I use it with lithium batteries?
How do I program and monitor it?
Is it UL listed?
Is the charger 220 A or 200 A?
What size cables and fuse do I need?
How does the warranty work?
Questions About Your Setup? Ask Us First.