Skip to product information

Victron Energy

Victron Energy MultiPlus 24/2000/50-50 120V Pure Sine Wave Inverter Charger, 2000VA 1600W, 50A Charger, 50A Transfer Switch, UL 458, PMP242200102

Victron Energy MultiPlus 24/2000/50-50 120V Pure Sine Wave Inverter Charger, 2000VA 1600W, 50A Charger, 50A Transfer Switch, UL 458, PMP242200102

⚑ 2000VA / 1600W Pure Sine Inverter|πŸ”‹ 50A Adaptive Charger|πŸ” 50A Transfer Switch, PowerAssist|πŸ›‘οΈ 5-Year Victron Warranty
Regular price
Price: $785.40
Regular price
List Price: $0.00
Sale price
Price: $785.40
View Cart
American Express Apple Pay Diners ClubDiscoverGoogle Pay Mastercard PayPalShop Pay Venmo Visa
In Stock – Ready to Ship
Free Shipping – Lower 48
Authorized Dealer – Full manufacturer warranty
Pay Over Time – Shop Pay Installments
Ships From US Warehouses
Real People – 833-664-7433
In stock & ready to ship. Free shipping to the lower 48.
  • πŸ‡ΊπŸ‡ΈFree ShippingContiguous 48 states
  • πŸ›‘οΈ5-Year WarrantyVictron limited warranty
  • ⚑3-in-1 UnitInverter, charger & transfer switch
  • βœ…UL 458 ListedPer Victron certification
  • πŸ”—ExpandableParallel & 3-phase capable
  • πŸ“žReal Human SupportSystem sizing & setup help

Victron Energy MultiPlus 24/2000/50-50 120V (PMP242200102): a pure sine wave inverter, battery charger and automatic transfer switch in one unit. Run 120V AC loads from your 24V battery bank with 2000 VA / 1600 W of continuous pure sine wave power and 3500 W peak for motor starts. When shore power, a generator or the grid is connected, the 50 A adaptive charger refills your batteries and the 50 A transfer switch passes power through to your loads. PowerControl and PowerAssist make the most of limited shore or generator power. Backed by Victron's 5-year limited warranty.

2000 VA1600 W continuous
50 ABattery charger
50 ATransfer switch
3500 WPeak power

Ratings at 25Β°C (77Β°F) ambient, from Victron's datasheet. Output drops at higher temperatures, see the table below.

⚑ Is It Right for Your System?

Built for 24V battery banks powering standard 120V 60 Hz North American AC loads. Common uses:

  • RVs & campers
  • Boats & yachts
  • Off-grid cabins & solar
  • Home backup
  • Work trucks & vans
πŸ“ Quick check before you order:
  • Your battery bank is 24V (inverter input range 19–33 V).
  • Your AC loads stay within 1600 W continuous at 25Β°C, with short surges up to 3500 W. Installing somewhere hot? Check the temperature table below.
  • Your shore or generator input is up to 50 A. PowerControl lets you set a lower limit to match a smaller shore cord or generator.
  • Plan for battery cables, a DC fuse and AC wiring sized per Victron's manual (not included).
  • Need UL? This model carries UL 458.
Not sure? Tell us your loads and battery bank and we'll help you size it before you buy.

Why Choose a Victron MultiPlus

πŸ”

Three Units in One

A pure sine wave inverter, an adaptive battery charger and an automatic transfer switch share one box, saving space and wiring.

πŸ”Œ

PowerControl & PowerAssist

Set a maximum shore or generator current. When loads spike past it, the MultiPlus adds battery power so the breaker doesn't trip.

πŸ”‹

Adaptive Battery Charging

A 50 A adaptive charger with battery temperature sensing, plus a 1 A output to keep a starter battery topped up.

πŸ”—

Grows With Your System

Parallel and 3-phase.

βš™οΈ

Programmable & Connected

Programmable relay: yes. VE.Bus connects it to Victron remote panels, GX devices and the VictronConnect app (with the right interface).

πŸ›‘οΈ

5-Year Victron Warranty

Victron covers the MultiPlus for 5 years from purchase by the original end user, and warranty claims go through us.

πŸŽ₯ Victron MultiPlus Videos

Update MultiPlus firmware from an Android phone (Victron Energy)

VE Configure basics (Victron Energy)

🌑️ Output vs. Temperature

Ambient temperature Continuous output
25Β°C (77Β°F) 2000 VA / 1600 W
40Β°C (104Β°F) 1400 W
65Β°C (149Β°F) 1000 W
Peak (short surges) 3500 W

Per Victron's datasheet. Mount it somewhere cool and well ventilated to get the most out of it.

πŸ“¦ What's Included & What You'll Need

  • Victron Energy MultiPlus 24/2000/50-50 120VVictron MultiPlus 24/2000/50-50 120VPart number PMP242200102
  • Battery Cables & DC FuseNot included. Size them per Victron's manual
  • Programming InterfaceMK3-USB (VEConfigure) or VE.Bus Smart dongle (VictronConnect). Sold separately
  • Remote Panel (optional)Digital Multi Control for on/off and shore current limit. Sold separately
  • GX Device (optional)e.g. Cerbo GX for remote monitoring on Victron's VRM portal. Sold separately
Plan to add: Victron doesn't publish a box contents list. Expect the inverter/charger itself; wiring, fusing, a programming interface and remote panels are bought separately. Ask us and we'll put together everything your install needs.

πŸ” Compare Victron MultiPlus Models

Every MultiPlus we carry, side by side. All ratings are from Victron at 25Β°C.

Model Battery Inverter Charger Transfer AC UL
MultiPlus 12/1200/50-16 120V 12V 1200 VA / 1000 W 50 A 16 A 120V Not UL listed
MultiPlus 12/2000/80-50 120V 12V 2000 VA / 1600 W 80 A 50 A 120V UL 458
MultiPlus 24/2000/50-50 120V (this model) 24V 2000 VA / 1600 W 50 A 50 A 120V UL 458
MultiPlus Compact 12/2000/80-50 120V 12V 2000 VA / 1600 W 80 A 50 A 120V UL 458
MultiPlus 12/3000/120-50 120V 12V 3000 VA / 2400 W 120 A 50 A 120V Not UL listed
MultiPlus 12/3000/120-50 120V UL 12V 3000 VA / 2400 W 120 A 50 A 120V UL 1741 & UL 458
MultiPlus 24/3000/70-50 120V UL 24V 3000 VA / 2400 W 70 A 50 A 120V UL 1741 & UL 458
MultiPlus 12/3000/120-50 230V 12V 3000 VA / 2400 W 120 A 50 A 230V Not UL listed

Need help choosing? Call 833-664-7433 and we'll size it to your loads.

πŸ”‹ Charging Your Batteries

πŸ”‹

Lithium or Lead-Acid

Default charge voltages are 28.8 V / 27.6 V / 26.4 V (absorption / float / storage). Adjust them with DIP switches or VEConfigure to match your battery maker's specs.

πŸ”Œ

Shore, Generator or Grid

Charges from 95–140 VAC AC input, and PowerControl keeps it within your shore or generator limit.

🚀

Starter Battery Output

A separate 1 A output keeps an engine or starter battery charged.

🌑️

Temperature Compensation

A battery temperature sensor input adjusts charging for hot and cold conditions.

πŸ›‘οΈ 5-Year Victron Limited Warranty

Years 1–5Victron limited warranty from the original end user's purchase date (max 66 months from Victron's invoice date)
Up to Year 10Optional extension to 10 years, sold through Victron's direct customers. Ask us about eligibility.

Warranty claims are made through the place of purchase, which is us. Victron's warranty doesn't cover physical damage or alteration, misuse (reversed polarity, poor or loose connections, liquid or condensation, lightning), improper installation, repairs by anyone other than Victron or an authorized repair centre, or the cost of removal, shipping and reinstallation. Full terms in Victron's warranty policy below.

πŸ“‹ Full Specifications

Inverter
Model / Part Number MultiPlus 24/2000/50-50 120V / PMP242200102
Battery Voltage 24V (input range 19–33 V)
AC Output 120 VAC Β±2%, 60 Hz Β±0.1% (adjustable to 50 Hz)
Continuous Power at 25Β°C 2000 VA / 1600 W
Continuous Power at 40Β°C / 65Β°C 1400 W / 1000 W
Peak Power 3500 W
Max Efficiency 94%
Zero-Load Power 11 W
Search Mode Power 4 W
Charger & Transfer Switch
AC Input 95–140 VAC
Charge Voltage (absorption / float / storage) 28.8 V / 27.6 V / 26.4 V
House Battery Charge Current 50 A (at 25Β°C)
Starter Battery Charge Current 1 A
Battery Temperature Sensor Yes
Transfer Switch 50 A
PowerControl / PowerAssist Yes
System & Control
Parallel / 3-Phase Yes, parallel and 3-phase
Programmable Relay Yes (4 A at AC voltage, 4 A up to 35 VDC, 1 A up to 60 VDC)
VE.Bus Port Yes, for parallel/3-phase, remote panels and GX devices
Remote On/Off On / off
DIP Switches Yes
Protection Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, AC voltage on inverter output, input voltage ripple too high
Operating Temperature -40 to +65Β°C (fan assisted)
Humidity Max 95%, non-condensing
Enclosure & Certifications
Enclosure Steel, blue (RAL 5012)
Protection Category IP22
Battery Connection M8 bolts
AC Connection Screw terminals, 13 mmΒ² (6 AWG)
Weight 15.5 kg (about 34 lb)
Dimensions (H Γ— W Γ— D) 506 Γ— 236 Γ— 147 mm
Safety Standards EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1; ECE R10-5
Warranty 5-year Victron limited warranty

πŸ“„ Manuals & Downloads

Victron doesn't publish a box contents list for the MultiPlus. Manuals and certificates above link straight to Victron.

❓ Common Questions

What's the difference between VA and watts?
VA is apparent power and watts are the real power your appliances use. This MultiPlus delivers 2000 VA, which is 1600 W of continuous power at 25Β°C. Add up the watts of everything you'll run at once and stay under 1600 W.
Will it start my air conditioner, microwave or pump?
Motors and compressors pull a short surge when they start. This model handles surges up to 3500 W, with 1600 W continuous. Send us the appliance labels and we'll confirm.
Will it work on smaller shore power or a small generator?
Yes. PowerControl lets you set the maximum AC input current (up to 50 A), and PowerAssist adds battery power during peaks so a small shore connection or generator doesn't trip.
Can I use it with lithium batteries?
Yes. The charge voltages are adjustable with DIP switches or VEConfigure, so you can match your lithium battery maker's settings. Ask us about pairing it with a GX device for battery communication.
How do I program and monitor it?
Use an MK3-USB interface with Victron's free VEConfigure software on a PC, or a VE.Bus Smart dongle with the VictronConnect app over Bluetooth. Add a GX device like the Cerbo GX for remote monitoring on Victron's VRM portal. All are sold separately.
Can I connect more than one?
Parallel and 3-phase. Units must be the same model and configured with Victron's software.
Do I need a UL listed inverter charger?
Many RV builders, inspectors and permit offices ask for UL 458 (mobile and marine power converters) or UL 1741 (grid-tied systems). This model carries UL 458.
What size cables and fuse do I need?
Victron's installation manual lists the recommended battery cable size and DC fuse for this model. Linked above in Manuals & Downloads, or ask us and we'll spec your wiring.
How does the warranty work?
Victron covers it for 5 years from the original end user's purchase date. Warranty claims go through the place of purchase, so contact us and we'll handle it with Victron.

Questions About Your Setup? Ask Us First.

Tell us your battery bank, your biggest AC loads and your shore or generator power, and we'll confirm the right MultiPlus before you order.