Skip to product information

Victron Energy

Victron Energy Lynx Smart BMS 1000A (M10) Battery Management System for Victron Lithium Battery Smart, 12V/24V/48V, Bluetooth, VE.Can, LYN034170210

Victron Energy Lynx Smart BMS 1000A (M10) Battery Management System for Victron Lithium Battery Smart, 12V/24V/48V, Bluetooth, VE.Can, LYN034170210

⚑ 1000A Lithium BMS|πŸ“Š Built-In Battery Monitor|πŸ“± Bluetooth & VE.Can|πŸ›‘οΈ 5-Year Victron Warranty
Regular price
Price: $1,178.10
Regular price
List Price: $0.00
Sale price
Price: $1,178.10
View Cart
In Stock – Ready to Ship
Free Shipping, Lower 48
Manufacturer Warranty
Call Us 833-664-7433
  • πŸ‡ΊπŸ‡ΈFree ShippingContiguous 48 states
  • πŸ›‘οΈ5-Year WarrantyVictron limited warranty
  • ⚑1000 A Contactor1200 A for 5 minutes
  • πŸ“ŠBuilt-In Battery MonitorSoC, voltage & current
  • πŸ“±Bluetooth & VE.CanVictronConnect, GX & VRM
  • πŸ“žReal Human SupportSystem design help

Victron Energy Lynx Smart BMS 1000 (M10) (LYN034170210): a dedicated battery management system for Victron Lithium Battery Smart banks, with a 1000 A main contactor, a built-in battery monitor, Bluetooth and VE.Can. The Lynx Smart BMS protects a 12V, 24V or 48V bank of Victron Lithium Battery Smart batteries and switches the whole system with its built-in 1000 A contactor. It warns you before it shuts loads down, controls Victron chargers and inverters through DVCC on a GX device, and doubles as a full battery monitor, so you don't need a separate shunt. It bolts straight into a Lynx busbar system with up to four Lynx Distributors. Note: this is the original Lynx Smart BMS for Lithium Battery Smart. For Victron Lithium NG batteries, you need the Lynx Smart BMS 1000 NG (LYN034170310). Backed by Victron's 5-year limited warranty.

1000 AContinuous contactor
1200 APeak for 5 minutes
9–60 VSystem voltage range
20Batteries per BMS (max)

Ratings from Victron's datasheet and manual.

πŸ”‹ Is It Right for Your System?

Built for 12V, 24V or 48V banks of Victron Lithium Battery Smart (12.8V and 25.6V) in Lynx busbar systems. Common uses:

  • Yachts & catamarans
  • Large RVs & expedition trucks
  • Off-grid homes
  • ESS & backup systems
  • Workboats & industrial
πŸ“ Quick check before you order:
  • Your batteries are Victron Lithium Battery Smart (12.8V or 25.6V). It doesn't support Lithium NG or SuperPack batteries. For Lithium NG, choose the Lynx Smart BMS NG.
  • Your bank is up to 4 Γ— 12.8V or 2 Γ— 25.6V in series, with up to 20 batteries total (up to 84 kWh at 12V or 102 kWh at 24V/48V).
  • Your system current stays within 1000 A continuous.
  • You'll add fusing. The BMS isn't a system fuse; use Lynx Distributors or other fuses for each load and charger circuit.
  • You'll mount it indoors in a dry place (IP22) and connect it to Lynx modules with M10 busbars.
  • Need UL? Victron doesn't list UL or CSA certification for this BMS. Call us if your inspector needs specific paperwork.
Not sure? Tell us your batteries and system layout, and we'll confirm the right BMS before you buy.

Why Choose the Victron Lynx Smart BMS

πŸ›‘οΈ

Battery Protection

Monitors every cell through the battery BMS cables and disconnects loads or chargers to prevent over-discharge, overcharge and low-temperature charging.

⚑

1000 A Contactor

A built-in contactor acts as a secondary safety and a remote main switch, controlled from VictronConnect, a GX device or remote on/off terminals.

⏰

Pre-Alarm

Warns at least 30 seconds before it shuts loads down, through the programmable relay and VictronConnect.

πŸ“Š

Built-In Battery Monitor

Shows state of charge, voltage, current and history, with Instant Readout, so you don't need a separate shunt.

🌐

GX, DVCC & VRM

Connect over VE.Can to a Cerbo GX to control Victron chargers and inverters automatically and monitor remotely on VRM.

πŸ”©

Lynx Modular Busbar

Bolts into a Lynx Distributor and Lynx Power In system with M10 busbars for a clean, compact install.

πŸŽ₯ Video from Victron

Explanation of the Victron Lynx Smart BMS for lithium battery management

πŸ”‹ System Limits

Limit Value
Supported batteries Victron Lithium Battery Smart 12.8V and 25.6V
Max in series 4 Γ— 12.8V or 2 Γ— 25.6V
Max batteries 20 per BMS
Max bank size 84 kWh (12V) / 102 kWh (24V and 48V)
Parallel BMSes Up to 5 (can be mixed with Lynx Smart BMS NG units of the same rating)

From Victron's manual. Each BMS manages only its own battery type.

πŸ“¦ What's Included & What You'll Need

  • Victron Energy Lynx Smart BMS 1000 (M10)Victron Lynx Smart BMS 1000 (M10)Part number LYN034170210
  • Lithium Battery SmartNot included. Required (12.8V or 25.6V)
  • Lynx Distributor & FusesNot included. The BMS isn't a system fuse
  • GX Device (Optional)Not included. Cerbo GX for DVCC and VRM
Plan to add: Victron Lithium Battery Smart batteries, fuses or Lynx Distributors, battery cables and, for DVCC and VRM, a GX device such as the Cerbo GX. Victron doesn't publish a box contents list. Ask us and we'll design the full system with you.

πŸ” Compare Victron Lynx Smart BMS Models

The Lynx Smart BMS family side by side. The NG and non-NG versions support different batteries.

Model Part # Contactor Busbar Supported batteries
Lynx Smart BMS 500 (M8) LYN034160200 500 A M8 Lithium Battery Smart
Lynx Smart BMS 500 (M10) LYN034160210 500 A M10 Lithium Battery Smart
Lynx Smart BMS 1000 (M10) (this model) LYN034170210 1000 A M10 Lithium Battery Smart
Lynx Smart BMS 500 NG (M10) LYN034160310 500 A M10 Lithium NG
Lynx Smart BMS 1000 NG (M10) LYN034170310 1000 A M10 Lithium NG

Need a different model? Call 833-664-7433 and we'll quote it.

🧰 Connections & Control

πŸ”Œ

ATC / ATD Contacts

Allowed-to-charge and allowed-to-discharge contacts (0.5 A at 60 VDC) for non-GX chargers and loads.

πŸ””

Programmable Relay

SPDT relay, 2 A at 60 VDC, for alarm, pre-alarm or alternator control.

⚑

AUX Output

1.1 A continuous at system voltage to keep a GX device powered after a low-cell shutdown.

🎚️

Remote On/Off

Use the remote terminals, VictronConnect or a GX device to switch the system on or off.

πŸ›‘οΈ 5-Year Victron Limited Warranty

Years 1–5Victron limited warranty from the original end user's purchase date (max 66 months from Victron's invoice date)
Up to Year 10Optional extension to 10 years, sold through Victron's direct customers. Ask us about eligibility.

Warranty claims are made through the place of purchase, which is us. Victron's warranty doesn't cover physical damage or alteration, misuse (reversed polarity, poor or loose connections, liquid or condensation, lightning), improper installation, repairs by anyone other than Victron or an authorized repair centre, or the cost of removal, shipping and reinstallation. Full terms in Victron's warranty policy below.

πŸ“‹ Full Specifications

BMS
Model / Part Number Victron Lynx Smart BMS 1000 (M10) / LYN034170210
Supported Batteries Victron Lithium Battery Smart 12.8V and 25.6V (not Lithium NG)
System Voltage 12, 24 or 48 V (9–60 VDC supply range)
Contactor Rating 1000 A continuous; 1200 A for 5 minutes
Pre-Alarm Configurable; at least 30 seconds before load shutdown
Battery Monitor Built in (state of charge, voltage, current, history)
Self-Consumption About 4.2 W on; about 0.6 W standby; 0.3 mA off
Connections & Control
Bluetooth Yes: VictronConnect, Instant Readout
Communication VE.Can (RJ45) to a GX device; NMEA 2000 with an adapter cable
ATC / ATD 0.5 A at 60 VDC each, resettable fuses
Programmable Relay SPDT, 2 A at 60 VDC
AUX Output 1.1 A continuous at system voltage
Busbar M10, tinned copper, 33 Nm
Lynx Integration Up to 4 Lynx Distributors via RJ10
Physical & Certifications
Protection Category IP22 (indoor, dry locations)
Operating Temperature -40 to +60Β°C
Weight 2.7 kg (6 lb)
Dimensions (H Γ— W Γ— D) 230 Γ— 180 Γ— 100 mm (9.1 Γ— 7.1 Γ— 3.9 in)
Certifications EN-IEC 61000-6-3, EN-IEC 63000, EU RED; Victron doesn't list UL or CSA
Warranty 5-year Victron limited warranty

πŸ“„ Manuals & Downloads

Manuals, drawings and product pages above link straight to Victron.

❓ Common Questions

Will it work with Victron Lithium NG or SuperPack batteries?
No. This BMS is for Victron Lithium Battery Smart. Lithium NG batteries need the Lynx Smart BMS NG (LYN034170310), and SuperPack NG batteries have their own built-in BMS.
Do I still need a battery monitor?
No. The Lynx Smart BMS has a built-in shunt and battery monitor that shows state of charge, voltage, current and history.
Is it a fuse?
No. The BMS contactor isn't a system fuse. Fuse each circuit with Lynx Distributors or other suitable fuses.
How does it control my chargers and inverter?
With a GX device (such as the Cerbo GX), it controls Victron chargers and inverters through DVCC. Non-GX equipment can use the allowed-to-charge and allowed-to-discharge contacts.
Can I parallel two BMSes?
Yes, up to 5. Victron says Lynx Smart BMS units can be paralleled with Lynx Smart BMS NG units of the same current rating, with each BMS managing its own batteries.
Is it UL listed?
Victron doesn't list UL or CSA certification for the Lynx Smart BMS. Call us if your inspector needs specific paperwork.
How does the warranty work?
Victron covers it for 5 years from the original end user's purchase date. Warranty claims go through the place of purchase, so contact us and we'll handle it with Victron.

Questions About Your Setup? Ask Us First.

Tell us your batteries, system voltage and loads, and we'll confirm whether you need the Lynx Smart BMS or the NG version before you order.