Victron Energy
Victron Energy Lynx Smart BMS 1000A (M10) Battery Management System for Victron Lithium Battery Smart, 12V/24V/48V, Bluetooth, VE.Can, LYN034170210
Victron Energy Lynx Smart BMS 1000A (M10) Battery Management System for Victron Lithium Battery Smart, 12V/24V/48V, Bluetooth, VE.Can, LYN034170210
- Regular price
- Price: $1,178.10
- Regular price
- List Price: $0.00
- Sale price
- Price: $1,178.10
- Unit price
- / per
Notify me when this product is available:
Couldn't load pickup availability
PRODUCT DESCRIPTION
- πΊπΈFree ShippingContiguous 48 states
- π‘οΈ5-Year WarrantyVictron limited warranty
- β‘1000 A Contactor1200 A for 5 minutes
- πBuilt-In Battery MonitorSoC, voltage & current
- π±Bluetooth & VE.CanVictronConnect, GX & VRM
- πReal Human SupportSystem design help
Victron Energy Lynx Smart BMS 1000 (M10) (LYN034170210): a dedicated battery management system for Victron Lithium Battery Smart banks, with a 1000 A main contactor, a built-in battery monitor, Bluetooth and VE.Can. The Lynx Smart BMS protects a 12V, 24V or 48V bank of Victron Lithium Battery Smart batteries and switches the whole system with its built-in 1000 A contactor. It warns you before it shuts loads down, controls Victron chargers and inverters through DVCC on a GX device, and doubles as a full battery monitor, so you don't need a separate shunt. It bolts straight into a Lynx busbar system with up to four Lynx Distributors. Note: this is the original Lynx Smart BMS for Lithium Battery Smart. For Victron Lithium NG batteries, you need the Lynx Smart BMS 1000 NG (LYN034170310). Backed by Victron's 5-year limited warranty.
Ratings from Victron's datasheet and manual.
π Is It Right for Your System?
Built for 12V, 24V or 48V banks of Victron Lithium Battery Smart (12.8V and 25.6V) in Lynx busbar systems. Common uses:
- Yachts & catamarans
- Large RVs & expedition trucks
- Off-grid homes
- ESS & backup systems
- Workboats & industrial
- Your batteries are Victron Lithium Battery Smart (12.8V or 25.6V). It doesn't support Lithium NG or SuperPack batteries. For Lithium NG, choose the Lynx Smart BMS NG.
- Your bank is up to 4 Γ 12.8V or 2 Γ 25.6V in series, with up to 20 batteries total (up to 84 kWh at 12V or 102 kWh at 24V/48V).
- Your system current stays within 1000 A continuous.
- You'll add fusing. The BMS isn't a system fuse; use Lynx Distributors or other fuses for each load and charger circuit.
- You'll mount it indoors in a dry place (IP22) and connect it to Lynx modules with M10 busbars.
- Need UL? Victron doesn't list UL or CSA certification for this BMS. Call us if your inspector needs specific paperwork.
Why Choose the Victron Lynx Smart BMS
Battery Protection
Monitors every cell through the battery BMS cables and disconnects loads or chargers to prevent over-discharge, overcharge and low-temperature charging.
1000 A Contactor
A built-in contactor acts as a secondary safety and a remote main switch, controlled from VictronConnect, a GX device or remote on/off terminals.
Pre-Alarm
Warns at least 30 seconds before it shuts loads down, through the programmable relay and VictronConnect.
Built-In Battery Monitor
Shows state of charge, voltage, current and history, with Instant Readout, so you don't need a separate shunt.
GX, DVCC & VRM
Connect over VE.Can to a Cerbo GX to control Victron chargers and inverters automatically and monitor remotely on VRM.
Lynx Modular Busbar
Bolts into a Lynx Distributor and Lynx Power In system with M10 busbars for a clean, compact install.
π₯ Video from Victron
Explanation of the Victron Lynx Smart BMS for lithium battery management
π System Limits
| Limit | Value |
|---|---|
| Supported batteries | Victron Lithium Battery Smart 12.8V and 25.6V |
| Max in series | 4 Γ 12.8V or 2 Γ 25.6V |
| Max batteries | 20 per BMS |
| Max bank size | 84 kWh (12V) / 102 kWh (24V and 48V) |
| Parallel BMSes | Up to 5 (can be mixed with Lynx Smart BMS NG units of the same rating) |
From Victron's manual. Each BMS manages only its own battery type.
π¦ What's Included & What You'll Need
-
Victron Lynx Smart BMS 1000 (M10)Part number LYN034170210
- Lithium Battery SmartNot included. Required (12.8V or 25.6V)
- Lynx Distributor & FusesNot included. The BMS isn't a system fuse
- GX Device (Optional)Not included. Cerbo GX for DVCC and VRM
π Compare Victron Lynx Smart BMS Models
The Lynx Smart BMS family side by side. The NG and non-NG versions support different batteries.
| Model | Part # | Contactor | Busbar | Supported batteries |
|---|---|---|---|---|
| Lynx Smart BMS 500 (M8) | LYN034160200 | 500 A | M8 | Lithium Battery Smart |
| Lynx Smart BMS 500 (M10) | LYN034160210 | 500 A | M10 | Lithium Battery Smart |
| Lynx Smart BMS 1000 (M10) (this model) | LYN034170210 | 1000 A | M10 | Lithium Battery Smart |
| Lynx Smart BMS 500 NG (M10) | LYN034160310 | 500 A | M10 | Lithium NG |
| Lynx Smart BMS 1000 NG (M10) | LYN034170310 | 1000 A | M10 | Lithium NG |
Need a different model? Call 833-664-7433 and we'll quote it.
π§° Connections & Control
ATC / ATD Contacts
Allowed-to-charge and allowed-to-discharge contacts (0.5 A at 60 VDC) for non-GX chargers and loads.
Programmable Relay
SPDT relay, 2 A at 60 VDC, for alarm, pre-alarm or alternator control.
AUX Output
1.1 A continuous at system voltage to keep a GX device powered after a low-cell shutdown.
Remote On/Off
Use the remote terminals, VictronConnect or a GX device to switch the system on or off.
π‘οΈ 5-Year Victron Limited Warranty
Warranty claims are made through the place of purchase, which is us. Victron's warranty doesn't cover physical damage or alteration, misuse (reversed polarity, poor or loose connections, liquid or condensation, lightning), improper installation, repairs by anyone other than Victron or an authorized repair centre, or the cost of removal, shipping and reinstallation. Full terms in Victron's warranty policy below.
π Full Specifications
| BMS | |
| Model / Part Number | Victron Lynx Smart BMS 1000 (M10) / LYN034170210 |
|---|---|
| Supported Batteries | Victron Lithium Battery Smart 12.8V and 25.6V (not Lithium NG) |
| System Voltage | 12, 24 or 48 V (9β60 VDC supply range) |
| Contactor Rating | 1000 A continuous; 1200 A for 5 minutes |
| Pre-Alarm | Configurable; at least 30 seconds before load shutdown |
| Battery Monitor | Built in (state of charge, voltage, current, history) |
| Self-Consumption | About 4.2 W on; about 0.6 W standby; 0.3 mA off |
| Connections & Control | |
| Bluetooth | Yes: VictronConnect, Instant Readout |
| Communication | VE.Can (RJ45) to a GX device; NMEA 2000 with an adapter cable |
| ATC / ATD | 0.5 A at 60 VDC each, resettable fuses |
| Programmable Relay | SPDT, 2 A at 60 VDC |
| AUX Output | 1.1 A continuous at system voltage |
| Busbar | M10, tinned copper, 33 Nm |
| Lynx Integration | Up to 4 Lynx Distributors via RJ10 |
| Physical & Certifications | |
| Protection Category | IP22 (indoor, dry locations) |
| Operating Temperature | -40 to +60Β°C |
| Weight | 2.7 kg (6 lb) |
| Dimensions (H Γ W Γ D) | 230 Γ 180 Γ 100 mm (9.1 Γ 7.1 Γ 3.9 in) |
| Certifications | EN-IEC 61000-6-3, EN-IEC 63000, EU RED; Victron doesn't list UL or CSA |
| Warranty | 5-year Victron limited warranty |
π Manuals & Downloads
Manuals, drawings and product pages above link straight to Victron.
β Common Questions
Will it work with Victron Lithium NG or SuperPack batteries?
Do I still need a battery monitor?
Is it a fuse?
How does it control my chargers and inverter?
Can I parallel two BMSes?
Is it UL listed?
How does the warranty work?
Questions About Your Setup? Ask Us First.
Tell us your batteries, system voltage and loads, and we'll confirm whether you need the Lynx Smart BMS or the NG version before you order.