- πReal Human SupportSystem sizing & setup help
Victron Energy MultiPlus 12/3000/120-50 230V (PMP123021010): a pure sine wave inverter, battery charger and automatic transfer switch in one unit. Run 230V AC loads from your 12V battery bank with 3000 VA / 2400 W of continuous pure sine wave power and 6000 W peak for motor starts. When shore power, a generator or the grid is connected, the 120 A adaptive charger refills your batteries and the 50 A transfer switch passes power through to your loads. PowerControl and PowerAssist make the most of limited shore or generator power. Backed by Victron's 5-year limited warranty.
Ratings at 25Β°C (77Β°F) ambient, from Victron's datasheet. Output drops at higher temperatures, see the table below.
β‘ Is It Right for Your System?
Built for 12V battery banks powering 230V 50 Hz AC loads (adjustable to 60 Hz). Common uses:
- 230V boats & yachts
- International & export systems
- 230V off-grid solar
- Mobile & commercial 230V systems
- Your battery bank is 12V (inverter input range 9.5β17 V).
- You need 230V AC. This model is not for standard North American 120V wiring. For 120V, see the MultiPlus 12/3000/120-50 120V.
- Your AC loads stay within 2400 W continuous at 25Β°C, with short surges up to 6000 W. Installing somewhere hot? Check the temperature table below.
- Your shore or generator input is up to 50 A. PowerControl lets you set a lower limit to match a smaller shore cord or generator.
- Plan for battery cables, a DC fuse and AC wiring sized per Victron's manual (not included).
- Need UL for an RV, inspection or permit? This version isn't UL listed. See the UL models in the comparison table below.
Why Choose a Victron MultiPlus
Three Units in One
A pure sine wave inverter, an adaptive battery charger and an automatic transfer switch share one box, saving space and wiring.
PowerControl & PowerAssist
Set a maximum shore or generator current. When loads spike past it, the MultiPlus adds battery power so the breaker doesn't trip.
Adaptive Battery Charging
A 120 A adaptive charger with battery temperature sensing, plus a 4 A output to keep a starter battery topped up.
Grows With Your System
Up to 6 in parallel; 3 units for 3-phase.
Programmable & Connected
Programmable relay: yes (3Γ). VE.Bus connects it to Victron remote panels, GX devices and the VictronConnect app (with the right interface).
5-Year Victron Warranty
Victron covers the MultiPlus for 5 years from purchase by the original end user, and warranty claims go through us.
π₯ Victron MultiPlus Videos
Update MultiPlus firmware from an Android phone (Victron Energy)
VE Configure basics (Victron Energy)
π‘οΈ Output vs. Temperature
| Ambient temperature | Continuous output |
|---|---|
| 25Β°C (77Β°F) | 3000 VA / 2400 W |
| 40Β°C (104Β°F) | 2200 W |
| 65Β°C (149Β°F) | 1700 W |
| Peak (short surges) | 6000 W |
Per Victron's datasheet. Mount it somewhere cool and well ventilated to get the most out of it.
π¦ What's Included & What You'll Need
-
Victron MultiPlus 12/3000/120-50 230VPart number PMP123021010
- Battery Cables & DC FuseNot included. Size them per Victron's manual
- Programming InterfaceMK3-USB (VEConfigure) or VE.Bus Smart dongle (VictronConnect). Sold separately
- Remote Panel (optional)Digital Multi Control for on/off and shore current limit. Sold separately
- GX Device (optional)e.g. Cerbo GX for remote monitoring on Victron's VRM portal. Sold separately
π Compare Victron MultiPlus Models
Every MultiPlus we carry, side by side. All ratings are from Victron at 25Β°C.
| Model | Battery | Inverter | Charger | Transfer | AC | UL |
|---|---|---|---|---|---|---|
| MultiPlus 12/1200/50-16 120V | 12V | 1200 VA / 1000 W | 50 A | 16 A | 120V | Not UL listed |
| MultiPlus 12/2000/80-50 120V | 12V | 2000 VA / 1600 W | 80 A | 50 A | 120V | UL 458 |
| MultiPlus 24/2000/50-50 120V | 24V | 2000 VA / 1600 W | 50 A | 50 A | 120V | UL 458 |
| MultiPlus Compact 12/2000/80-50 120V | 12V | 2000 VA / 1600 W | 80 A | 50 A | 120V | UL 458 |
| MultiPlus 12/3000/120-50 120V | 12V | 3000 VA / 2400 W | 120 A | 50 A | 120V | Not UL listed |
| MultiPlus 12/3000/120-50 120V UL | 12V | 3000 VA / 2400 W | 120 A | 50 A | 120V | UL 1741 & UL 458 |
| MultiPlus 24/3000/70-50 120V UL | 24V | 3000 VA / 2400 W | 70 A | 50 A | 120V | UL 1741 & UL 458 |
| MultiPlus 12/3000/120-50 230V (this model) | 12V | 3000 VA / 2400 W | 120 A | 50 A | 230V | Not UL listed |
Need help choosing? Call 833-664-7433 and we'll size it to your loads.
π Charging Your Batteries
Lithium or Lead-Acid
Default charge voltages are 14.4 V / 13.8 V / 13.2 V (absorption / float / storage). Adjust them with VEConfigure or VictronConnect to match your battery maker's specs.
Shore, Generator or Grid
Charges from 187β265 VAC, 45β65 Hz AC input, and PowerControl keeps it within your shore or generator limit.
Starter Battery Output
A separate 4 A output keeps an engine or starter battery charged.
Temperature Compensation
A battery temperature sensor input adjusts charging for hot and cold conditions.
π‘οΈ 5-Year Victron Limited Warranty
Warranty claims are made through the place of purchase, which is us. Victron's warranty doesn't cover physical damage or alteration, misuse (reversed polarity, poor or loose connections, liquid or condensation, lightning), improper installation, repairs by anyone other than Victron or an authorized repair centre, or the cost of removal, shipping and reinstallation. Full terms in Victron's warranty policy below.
π Full Specifications
| Inverter | |
| Model / Part Number | MultiPlus 12/3000/120-50 230V / PMP123021010 |
|---|---|
| Battery Voltage | 12V (input range 9.5β17 V) |
| AC Output | 230 VAC Β±2%, 50 Hz Β±0.1% (adjustable to 60 Hz) |
| Continuous Power at 25Β°C | 3000 VA / 2400 W |
| Continuous Power at 40Β°C / 65Β°C | 2200 W / 1700 W |
| Peak Power | 6000 W |
| Max Efficiency | 93% |
| Zero-Load Power | 20 W |
| AES Mode Power | 15 W |
| Search Mode Power | 8 W |
| Charger & Transfer Switch | |
| AC Input | 187β265 VAC, 45β65 Hz |
| Power Factor | 1 |
| Charge Voltage (absorption / float / storage) | 14.4 V / 13.8 V / 13.2 V |
| House Battery Charge Current | 120 A (at 25Β°C) |
| Starter Battery Charge Current | 4 A |
| Battery Temperature Sensor | Yes |
| Transfer Switch | 50 A |
| PowerControl / PowerAssist | Yes |
| System & Control | |
| Parallel / 3-Phase | Yes, up to 6 in parallel; 3 units for 3-phase |
| Auxiliary Output | Yes (16 A) |
| Programmable Relay | Yes (3Γ) (4 A at AC voltage, 4 A up to 35 VDC, 1 A up to 60 VDC) |
| Communication Ports | Yes |
| VE.Bus Port | Yes, for parallel/3-phase, remote panels and GX devices |
| Remote On/Off | Yes |
| Protection | Output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, AC voltage on inverter output, input voltage ripple too high |
| Operating Temperature | -40 to +65Β°C (fan assisted) |
| Humidity | Max 95%, non-condensing |
| Enclosure & Certifications | |
| Enclosure | Aluminium, blue (RAL 5012) |
| Protection Category | IP20 |
| Battery Connection | Four M8 bolts |
| AC Connection | Screw terminals, 13 mmΒ² (6 AWG), M6 bolts |
| Weight | 18 kg (about 40 lb) |
| Dimensions (H Γ W Γ D) | 364 Γ 295 Γ 221 mm |
| Safety Standards | EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1; ECE R10-4 |
| Warranty | 5-year Victron limited warranty |
π Manuals & Downloads
Victron doesn't publish a box contents list for the MultiPlus. Manuals and certificates above link straight to Victron.
β Common Questions
What's the difference between VA and watts?
Will it start my air conditioner, microwave or pump?
Will it work on smaller shore power or a small generator?
Can I use it with lithium batteries?
How do I program and monitor it?
Can I connect more than one?
Can I use this in a US home or RV?
What size cables and fuse do I need?
How does the warranty work?
Questions About Your Setup? Ask Us First.
Tell us your battery bank, your biggest AC loads and your shore or generator power, and we'll confirm the right MultiPlus before you order.